Reject Options
Side Push Arm (mounted on take away)
Side Air Blast (mounted on take away)
End of line Case X-Ray beam
coverage
At 250mm
High = 680mm Wide
At 380mm
High = 610mm Wide
At 450mm
High = 530mm Wide
At 530mm
High = 450mm Wide
IP66 Model (Standard model IP65)
High pressure Washdown
A/C (water cooled) Dehumidification/Cooling
304 Stainless - #3 finish cabinet
Stainless steel roll out conveyor
Operating temperature: 0 Deg. C to 50 Deg. C
Service requirements
Power: 200-240 VAC, 50/60 Hz, 20 Amp, Single phase
Compressed air: 80 psi- 3/8" Line, Dry and filtered